Surgical Technologies Medical Education
Tools and Attachments Quiz #2

Back To Quizzes
1  Legend Variable Exposure Attachments can be distinguished from Legend Standard Attachments by their double color bands located on the attachments.
A. True
B. False
Please choose the best answer:

True False

2  To ensure proper cleaning of the Legend Variable Exposure Attachment:
A. Soak the attachment for 45 minutes.
B. The Legend Variable Exposure Attachment is disposable and no cleaning is required.
C. Clean the attachment completely, first without adjusting the tube length, then with the tube fully extended and then with the tube fully retracted.
D. Clean the attachment completely by rapidly extending and retracting the attachment several times while spraying cleaning fluid into the attachment.
Please choose the best answer:

A B C D

3  The tube adjustment ring on Legend Variable Exposure Attachments is used to adjust the exposure of the dissecting tool. In order to decrease the exposure of the dissecting tool, it is necessary to:
A. Turn the ring to the right to increase the length of the tube
B. Turn the ring to the left to increase the length of the tube
C. Turn the ring to the right to decrease the length of the tube
D. Turn the ring to the left to decrease the length of the tube
Please choose the best answer:

A B C D

4  Which of the following items(s) require the AT10 Telescoping Attachment?
A. Curved Bur Tool
B. Telescoping Tube
C. 9 MH 30 D
D. A and B
E. B and C
Please choose the best answer:

A B C D E

5  Prior to the initial use of the Curved Bur Tool, soak the cooling sleeve by dipping the tool into a cup of saline or distilled water.
A. True
B. False
Please choose the best answer:

True False

6  While using the Curved Bur Tool, it is important to:
A. Moisten the tool only at the beginning of surgery
B. Maintain copious irrigation of the cooling sleeve and bur tip during use
C. Avoid having the cooling sleeve come in contact with irrigation fluids
D. None of the above
Please choose the best answer:

A B C D

7  What is the maximum continuous cutting time for 3 and 4 millimeter Curved Burs?
A. 1 minute
B. 10 minutes
C. 4 minutes
D. 3 minutes
Please choose the best answer:

A B C D

8  What is the maximum total cutting time for 1 and 2 millimeter Curved Burs?
A. 3 minutes
B. 5 minutes
C. 12 minutes
D. 18 minutes
Please choose the best answer:

A B C D

9  If the Curved Bur Tool does not rotate or does not cut bone when pressure is applied, the user needs to confirm that the:
A. Bur is pressed firmly into the drill
B. Tool locking ring is in the locked position
C. Curved Bur hub is fully inserted into the AT10 attachment and the tube locking ring is in the locked position.
D. All of the above.
Please choose the best answer:

A B C D

10  After the installation of an attachment and tool, it is essential to briefly run the motor for the following reason(s):
A. To check the motor for overheating
B. To check for leaking lubricant
C. To check the attachment for overheating
D. To check the dissecting tool for flail
E. All of the above
Please choose the best answer:

A B C D E

11  Cleaning brushes are used to clean debris from the lumen of attachments and telescoping tubes. These brushes are designed to pass through which of the following attachments:
A. AS09
B. Metal cutting
C. Angled attachments
D. Perforators
Please choose the best answer:

A B C D

 

 

Quiz Results



Final Score: out of


Back To Quizzes